Cleanrooms in Focus

CSM®-certified flooring systems for controlled environments

Cleanrooms are about much more than just cleanliness.

This is where highly sensitive products such as pharmaceuticals, implants, diagnostic systems, and microelectronic components are developed, manufactured, and processed.

Contaminants pose a risk

In cleanrooms, contamination is controlled to protect sensitive products, processes, and research results. Particle emissions, cleanability, and the durability of the surfaces used have a direct impact on the cleanliness of the environment.

Cleanroom flooring must ...

  • minimize particle generation.
  • withstand cleaning and disinfection processes.
  • be easy to clean.
  • limit microbial growth.

Purity classes and typical applications

Purity requirements are defined by the DIN EN ISO 14644 standard. It classifies cleanrooms into ISO classes 1 through 9 based on the permissible particle concentration. The lower the ISO class, the higher the air purity requirements.

In addition, the EU GMP guidelines apply to the manufacture of pharmaceuticals; these guidelines take into account not only particles but also microbiological contamination. GMP class A corresponds approximately to an ISO class 5 cleanroom.

CSM certification

The cleanroom suitability of materials is evaluated based on various criteria as part of the Fraunhofer IPA’s CSM® (Cleanroom Suitable Materials) program.

These criteria include particle emission, chemical and biological resistance, the cleanability of surfaces, and behavior during H₂O₂ decontamination processes. The test methods are based on recognized standards and guidelines and enable an objective assessment of materials’ suitability for contamination-critical environments.

VIASOL DESIGN QCV

Certified cleanroom compatibility for sensitive production, laboratory, and hygiene areas.

Zum Produkt

VIASOL DESIGN QCV conductive

Proven cleanroom suitability combined with conductive properties for ESD-sensitive areas.

Zum Produkt

What does the right solution feel like?

Sample service

Request a free sample

CSM® Testing criteria

 

Particulate emissions

Test standard: ISO 14644-1

The number of particles released by mechanical stress on the floor and their size distribution are determined.

→ The particles emitted by VIASOL systems do not compromise the air purity of an ISO 5 cleanroom.

Chemical resistance

Testing standard: ISO 2812-1, ISO 4628-1 and VDI 2083 Part 17

Resistance to a group of representative cleaning agents and disinfectants is tested.

→ The coating exhibits very good resistance to cleaning agents and disinfectants.

Biological resistance

Test Standard: ISO 846

The test determines whether bacteria and fungi can colonize or degrade the material.

Riboflavin test (cleanability)

Test standard: VDMA Information Sheet

This test evaluates how effectively a contaminated surface can be cleaned after three wipe-cleaning cycles. The material surface plays an important role in this process.

→ The contamination can be removed very easily.

H₂O₂ Absorption/Desorption

Test Standard: VDI 2083, Part 20

The time elapsed until the H2O2 concentration has dropped to one-tenth of its initial value is measured.

→ The VIASOL DESIGN QCV conductive is classified as “non-absorptive” with a decay time of < 5 min. H2O2 is practically not absorbed and is released again very quickly after ventilation. With a value of > 15 to ≤ 60 min, the VIASOL DESIGN QCV achieves the “medium” classification.

The right flooring system for your cleanroom

Are you planning a new cleanroom project or looking to modernize an existing area?

We’ll help you choose the right flooring system and guide you from planning through implementation with a solution that’s perfectly tailored to your needs and processes.